About the product

Product characteristics

  • Up to PLd in accordance with EN ISO 13849-1 and SIL2 in accordance with IEC 61508
  • Screwless terminals for easy installation
  • Status diagnostics via control outputs and LEDs
  • Number of sensors can be increased to 4 per sensor input.
  • By cascading, it is possible to connect up to 64 sensors to one safety control unit*

* To achieve the maximum performance level, it is necessary to integrate the control outputs in the evaluation (start interlock in the event of a fault). If interfaces are cascaded, this can result in a reduction of the maximum performance level PL. Connection examples are available from elobau.

Technical drawing

Electrical data

  • Attribute
  • Max. switching voltage at safety output
  • Max. switching voltage at control output
  • Max. switching current per channel
  • Number of electronic safety outputs
  • Number of electronic control outputs
  • Number of redundant safety inputs
  • Operating voltage min.
  • Operating voltage max.
  • Current consumption
  • Power consumption
  • LED display
  • Operating time
  • Fuse operating voltage
  • Pollution degree
  • Protection class
  • Overvoltage category
  • Contact form
Attribute 363G96K30 363G97 363V97 363096K30
Max. switching voltage at safety output 26.4 V DC
Max. switching voltage at control output 26.4 V DC
Max. switching current per channel 0.02 A
Number of electronic safety outputs 1
Number of electronic control outputs 1 4
Number of redundant safety inputs 4
Operating voltage min. 21.6 V DC
Operating voltage max. 26.4 V DC
Current consumption 100 mA
Power consumption 2.4 W
LED display single-coloured
Operating time 3000 ms
Fuse operating voltage 1A slow blow
Pollution degree 1
Protection class III
Overvoltage category III
Contact form NO/NC
Bestellung

Safety-related characteristics

  • Attribute
  • PL acc. to EN ISO 13849-1
  • SIL acc. to IEC 61508
  • SIL CL acc. to IEC 62061
  • PFHD according to IEC 61508
  • Category acc. to EN ISO 13849-1
  • Mission time in years
Attribute 363G96K30 363G97 363V97 363096K30
PL acc. to EN ISO 13849-1 d
SIL acc. to IEC 61508 2
SIL CL acc. to IEC 62061 2
PFHD according to IEC 61508 1,8*10^-8 1/h 1,05*10^-8 1/h 1,8*10^-8 1/h
Category acc. to EN ISO 13849-1 3
Mission time in years 20 a
Bestellung

Mechanical data

  • Attribute
  • Dimensions
  • Housing colour
Attribute 363G96K30 363G97 363V97 363096K30
Dimensions 96 x 51 x 56 mm (H/B/T)
Housing colour schwarz
Bestellung

Material information

  • Attribute
  • Housing material
Attribute 363G96K30 363G97 363V97 363096K30
Housing material PA
Bestellung

Environmental conditions

  • Attribute
  • Protection class
  • Protection class, installation space
  • Operating temperature min.
  • Max. operating temperature
  • Relative humidity
  • Min. storage temperature
  • Max. storage temperature
  • Shock resistance (Norm)
  • Continuous shock resistance (Norm)
  • Vibration resistance (Norm)
  • Air pressure
  • Delta tmax
Attribute 363G96K30 363G97 363V97 363096K30
Protection class IP00 DIN EN 60529
Protection class, installation space IP54 DIN EN 60529
Operating temperature min. 0 °C
Max. operating temperature 55 °C
Relative humidity 5 - 85 %
Min. storage temperature 0 °C
Max. storage temperature 55 °C
Shock resistance (Norm) 30 g / 11 ms
Continuous shock resistance (Norm) 10 g / 16 ms
Vibration resistance (Norm) 10...55 Hz
Air pressure 860 - 1060 hPa
Delta tmax 0.5 °C/min
Bestellung

Installation

  • Attribute
  • Mounting type
  • Weight
Attribute 363G96K30 363G97 363V97 363096K30
Mounting type Hutschiene
Weight 100 g
Bestellung

Connection

  • Attribute
  • Spring-type terminals
  • Pluggable connection terminals
  • Min. connection cross section
  • Max. connection cross section
Attribute 363G96K30 363G97 363V97 363096K30
Spring-type terminals yes
Pluggable connection terminals no
Min. connection cross section 0.08 mm^2
Max. connection cross section 2.5 mm^2
Bestellung

Approvals

  • Attribute
  • Certified in accordance with
  • CE label
Attribute 363G96K30 363G97 363V97 363096K30
Certified in accordance with EN ISO 13849-1, IEC 61508, UL 508/CSA 22.2
CE label yes
Bestellung

Product has been added to watchlist.