Skip to content
Climate neutral since 2010

eloProg relay modules 485EPR

eloProg relay modules 485EPR

  • Up to 4 safe, redundant relay outputs (NO contacts)
  • Diagnostics via up to 4 configurable control outputs and LEDs
  • Up to 4 EDM inputs for monitoring of downstream contactors or connection of a start push button
  • EDM output for return to base or output module
  • Depending on the variant, connection to the base module and other expansion modules with pre-assembled T-connector (proprietary 5-waybus) or wiring via connection terminals

The expansion modules with relay outputs have up to 4 force-guided NO relay contacts. They have been designed to handle 6A and 240V AC. In addition, up to 8 electronic control outputs are available for diagnostics.

Technical drawing

1/1
Cat_MS_SAE_485_Auswerteeinheit_DRW1
Full screen
1/1

Article characteristics

  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Utilization category
  • DC
  • Connection to output module
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Utilization category AC-15 / DC-13
DC Depending on the configuration %
Connection to output module via connection terminals
  • Electrical data
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Electrical data
  • Min. switching voltage at safety output
  • Max. switching voltage at safety output
  • Min. switching voltage at safety output
  • Max. switching voltage at safety output
  • Min. switching current at safety output
  • Max. switching current at safety output
  • Max. switching current at control output
  • Response time
  • Number of relay safety outputs
  • Number of relay control outputs
  • Feedback circuit
  • Operating voltage min.
  • Operating voltage max.
  • Power consumption
  • LED display
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Min. switching voltage at safety output 10 V DC
Max. switching voltage at safety output 250 V DC
Min. switching voltage at safety output 10 V AC
Max. switching voltage at safety output 400 V AC 230 V AC 400 V AC
Min. switching current at safety output 0.02 A
Max. switching current at safety output 6 A
Max. switching current at control output 0.1 A
Response time 12 ms
Number of relay safety outputs 2 4
Number of relay control outputs 8
Feedback circuit yes Depending on the configuration
Operating voltage min. 19.2 V DC
Operating voltage max. 28.8 V DC
Power consumption 3 W
LED display single-coloured No
  • Mechanical data
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Mechanical data
  • Service life, mechanical (Cycles)
  • Dimensions
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Service life, mechanical (Cycles) > 20 x 10^6 > 40 x 106
Dimensions 108 x 22,5 x 114,5 mm (H/B/T)
  • Material information
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Material information
  • Housing material
  • Housing colour
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Housing material PA
Housing colour Gehaeuse schwarz Frontplatte gelb
  • Environmental conditions
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Environmental conditions
  • Protection class, housing
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
  • Relative humidity
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Protection class, housing IP20 DIN EN 60529 IP54 DIN EN 60529
Operating temperature min. -10 °C
Max. operating temperature 55 °C
Min. storage temperature -20 °C
Max. storage temperature 85 °C
Relative humidity 10...95 %
  • Installation
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Installation
  • Mounting type
  • Weight
  • Torque for connection terminals
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Mounting type Mounting rail
Weight 181 g 231 g 255 g
Torque for connection terminals 0.6 N m
  • Connection
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Connection
  • Connection to base module
  • Screw terminals
  • Pluggable connection terminals
  • Min. connection cross section
  • Max. connection cross section
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Connection to base module via connection terminals propriertary 5-way bus (T-connector)
Screw terminals yes
Pluggable connection terminals yes
Min. connection cross section 0.5 mm²
Max. connection cross section 2.5 mm²
  • Approvals
  • 485EPR02
  • 485EPR04
  • 485EPR04S08B
  • Approvals
  • Certified in accordance with
  • CE label
Attribute485EPR02485EPR04485EPR04S08B
Bestellung
Bestellung
Certified in accordance with EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2
CE label yes
1/1
eloProg relay modules 485EPR | Up to 4 EDM inputs | elobau
Full screen
1/1

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.