Skip to content
Climate neutral since 2010

Angle sensor 424S

Angle sensor 424S

  • Long lifetime and extremely reliable from contactless measurement with Hall principle
  • IP67 protection class for harsh environmental conditions
  • High temperature resistance from -40 °C to +85 °C
  • Resolution 0.1°
  • Current or voltage output signal available
  • Switching output (push-pull / high-side / low-side) up to 1.5A
  • Available with AMP plug (Micro Quadlock System) or Deutsch plug DT04-6P

Angle sensor 424S has a redundant design and, as a result, is suitable for safety-critical measurement tasks. The sensor measures angles are between 30° and 120°. Angle sensor 424S is based on the contactless Hall measurement principle, which is extremely reliable and ensures a long service life. The sensor can be used for angle determination in telescopic arms of telescopic handlers and lifting platforms as well as for many other challenging off-highway applications.

Technical drawing

1/4
Cat_SENS_424S_DRW
Full screen
1/4
2/4
Cat_SENS_424S_CON
Full screen
2/4
3/4
Cat_SENS_424S_CD
Full screen
3/4
4/4
Cat_SENS_424S_FCT1
Full screen
4/4

Article characteristics

  • Electrical data
  • 424SD11D....
  • 424SD16D....
  • 424SD17D....
  • Electrical data
  • Polarity reversal protection
  • Output signal min.
  • Output signal max.
  • Output signal min.
  • Output signal max.
  • Output signal - centre position/zero position
  • Output signal - centre position/zero position
  • Output signal - switching point
  • Resolution
  • EMC Agricultural and forestry machines (Norm)
  • EMC Earth-moving and building construction machinery (Norm)
  • EMC Industrial trucks (Norm)
  • Operating voltage min.
  • Operating voltage max.
  • Max. overvoltage
  • Current consumption
  • Load resistance min.
  • Load resistance max.
  • Temperature coefficient
  • Typical linearity error
  • Signal sequence
  • Signal update rate
  • Outputs (quantity, type)
  • Max. switching current
  • Technology
  • Angle measuring range - analogue output
  • Angle range - switching output
  • Outputs
  • MTTF
Attribute424SD11D....424SD16D....424SD17D....
Bestellung
Bestellung
Polarity reversal protection yes
Output signal min. 0.5 V DC
Output signal max. 4.5 V DC
Output signal min. 4 mA
Output signal max. 20 mA
Output signal - centre position/zero position 2.5 V DC
Output signal - centre position/zero position 12 mA
Output signal - switching point Selectable (Highside, Lowside, Push-Pull)
Resolution 0.1 °
EMC Agricultural and forestry machines (Norm) EN ISO 14982
pulse 5b: max. voltage 54V (absolute), functional status C for pulse 1 and 4
EN ISO 14982
conducted disturbance not applicable for 5V supply
EN ISO 14982
pulse 5b: max. voltage 54V (absolute), functional status C for pulse 1 and 4
EMC Earth-moving and building construction machinery (Norm) DIN EN ISO 13766-1
pulse "load dump": max. voltage 54V (absolute)
DIN EN ISO 13766-1
conducted disturbance not applicable for 5V supply
DIN EN ISO 13766-1
pulse "load dump": max. voltage 54V (absolute)
EMC Industrial trucks (Norm) DIN EN 12895
Operating voltage min. 9 V DC 4.5 V DC 9 V DC
Operating voltage max. 32 V DC 5.5 V DC 32 V DC
Max. overvoltage (5min @ 25°C) 36 V DC 5.5 V DC (5min @ 25°C) 36 V DC
Current consumption 424SD11D.: 17.00 mA
424SD1.DH: 9.00 mA
424SD1.DL: 15.00 mA
424SD1.DS: 15.00 mA
424SD16D.: 9.00 mA
424SD1.DH: 9.00 mA
424SD1.DL: 15.00 mA
424SD1.DS: 15.00 mA
424SD17D.: 17.00 mA
424SD1.DH: 9.00 mA
424SD1.DL: 15.00 mA
424SD1.DS: 15.00 mA
Load resistance min. 20000 Ohm 10000 Ohm
Load resistance max. 9V: <150 Ohm
> 12V: <350 Ohm
Temperature coefficient typ. +- 250 ppm/K
Typical linearity error <= ±15°:±0,2°
<= ±25°:±0,4°
<= ±35°:±1,0°
<= ±45°:±2,0°
<= ±60°:±5,0°
Signal sequence CCW (CW on request)
Signal update rate 2000 Hz
Outputs (quantity, type) 2
Max. switching current Highside / Lowside: 1500 mA
Push-Pull: 0,25 mA
Technology Hall
Angle measuring range - analogue output 30° - 120° (selectable in 5° increments)
Angle range - switching output 0° - 120° (Selectable in 5° increments)
Outputs 4…20mA + switching output 0,5…4,5V ratiometric + Switching output 0,5...4,5V + Switching output
MTTF 424SD11D.: 72.2 a
424SD1.DH: 78.4 a
424SD1.DL: 87.1 a
424SD1.DS: 113.0 a
424SD16D.: 111.9 a
424SD1.DH: 78.4 a
424SD1.DL: 87.1 a
424SD1.DS: 113.0 a
424SD17D.: 79.6 a
424SD1.DH: 78.4 a
424SD1.DL: 87.1 a
424SD1.DS: 113.0 a
  • Mechanical data
  • 424SD11D....
  • 424SD16D....
  • 424SD17D....
  • Mechanical data
  • Max. shaft load, axial
  • Max. shaft load, radial
  • Bearing
  • Mechanical stop
  • Actuating lever
Attribute424SD11D....424SD16D....424SD17D....
Bestellung
Bestellung
Max. shaft load, axial 50 N
Max. shaft load, radial 100 N
Bearing Ball bearing
Mechanical stop Optional
Actuating lever Optional (Accessories: 350210)
  • Environmental conditions
  • 424SD11D....
  • 424SD16D....
  • 424SD17D....
  • Environmental conditions
  • Protection class
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
Attribute424SD11D....424SD16D....424SD17D....
Bestellung
Bestellung
Protection class IP67 DIN EN 60529 / IPX9K ISO 20653
Operating temperature min. -40 °C
Max. operating temperature 85 °C
Min. storage temperature -40 °C
Max. storage temperature 105 °C
  • Installation
  • 424SD11D....
  • 424SD16D....
  • 424SD17D....
  • Installation
  • Torque for fastening screws
Attribute424SD11D....424SD16D....424SD17D....
Bestellung
Bestellung
Torque for fastening screws 2.5 N m
  • Connection
  • 424SD11D....
  • 424SD16D....
  • 424SD17D....
  • Connection
  • Connector type
Attribute424SD11D....424SD16D....424SD17D....
Bestellung
Bestellung
Connector type Deutsch DT04-6P
1/1
424S_ordering-key
Full screen
1/1
Downloads
Manual 424 angle sensors pdf 1.78 MB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.