Skip to content
Climate neutral since 2010

eloProg base modules Standard

eloProg base modules Standard

  • 8 safety inputs and 2 solid-state safety output pairs (4 outputs) enable use as a stand-alone device
  • 4 test outputs for sensor monitoring
  • Diagnostics via 2 configurable control outputs and LEDs
  • 2 EDM inputs for monitoring of downstream contactors or connection of a start push button
  • Up to 14 expansion modules (up to 4 devices of any given module variant) can be connected
  • Optional 350EPT T-connector (proprietary 5-way bus) for space-saving connection of the base module with expansion modules
  • Optional 350EPU USB cable for transferring the configuration to the base module
  • Optional 350EPS memory card for data storage and base module configuration without PC

The base module is a configurable safety control unit that can be used as a stand-alone device. Communication with expansion modules is through an internal 5-way bus.

The safety function previously configured on the PC can be directly installed via USB. The base module also features a memory card slot.

Technical drawing

1/1
Cat_MS_SAE_485_Auswerteeinheit_DRW1
Full screen
1/1

Article characteristics

  • 485EPB
  • Housing colour
  • Max. switching voltage at safety output
  • Max. switching voltage at control output
  • Max. switching current at safety output
  • Max. switching current at control output
  • Number of configurable electronic safety outputs
  • Number of electronic control outputs
  • Number of test outputs (clocked)
  • Number of safety inputs
  • Stop category 0 (STO) nach IEC 61800-5-2
  • Stop category 1 (SS1) nach IEC 61800-5-2
  • EDM/start input
  • Start function
  • Feedback circuit
  • Start-up test present
  • LED display
  • Overvoltage category
  • Pollution degree
  • Operating voltage min.
  • Operating voltage max.
  • Short-circuit detection
  • Cross-short detection
  • Wire-break detection
  • Power consumption
  • Operating time
  • Response time
  • Contact form
  • PL acc. to EN ISO 13849-1
  • SIL acc. to IEC 61508
  • SIL CL acc. to IEC 62061
  • PFHD according to IEC 61508
  • MTTFd
  • Safe Failure Fraction (SFF) to IEC 61508
  • DC
  • Category acc. to EN ISO 13849-1
  • Type
  • Dimensions
  • Configuration interface
  • Housing material
  • Protection class, housing
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
  • Relative humidity
  • Mounting type
  • Weight
  • Max. length of the connection cables
  • Screw terminals
  • Pluggable connection terminals
  • Min. connection cross section
  • Max. connection cross section
  • Slot for memory card (350EPS) present
  • Connection present on PC
  • Connection to slave modules
  • Max. number of slave modules
  • Max. number of slave modules of the same type
  • Certified in accordance with
  • CE label
Attribute485EPB
Bestellung
Bestellung
Housing colour Gehäuse schwarz Frontplatte gelb
Max. switching voltage at safety output 24 V DC
Max. switching voltage at control output 24 V DC
Max. switching current at safety output 0.4 A
Max. switching current at control output 0.1 A
Number of configurable electronic safety outputs 4
Number of electronic control outputs 2
Number of test outputs (clocked) 4
Number of safety inputs 8
Stop category 0 (STO) nach IEC 61800-5-2 Depending on the configuration
Stop category 1 (SS1) nach IEC 61800-5-2 Depending on the configuration
EDM/start input Depending on the configuration
Start function Depending on the configuration
Feedback circuit Depending on the configuration
Start-up test present Depending on the configuration
LED display five-coloured
Overvoltage category II
Pollution degree 2
Operating voltage min. 19.2 V DC
Operating voltage max. 28.8 V DC
Short-circuit detection Depending on the configuration
Cross-short detection Depending on the configuration
Wire-break detection Depending on the configuration
Power consumption 3 W
Operating time Depending on the configuration ms
Response time 10,6 - 12,6 ms
Contact form Abhängig von der Konfiguration
PL acc. to EN ISO 13849-1 e
SIL acc. to IEC 61508 3
SIL CL acc. to IEC 62061 3
PFHD according to IEC 61508 6,85 x 10-9 1/h
MTTFd 30...100 a
Safe Failure Fraction (SFF) to IEC 61508 99.8 %
DC 99% <= DC (high) %
Category acc. to EN ISO 13849-1 4
Type 4 EN 61496-1
Dimensions 108 x 22,5 x 114,5 mm (H/B/T)
Configuration interface USB Mini-B
Housing material PA
Protection class, housing IP20 DIN EN 60529
Operating temperature min. -10 °C
Max. operating temperature 55 °C
Min. storage temperature -20 °C
Max. storage temperature 85 °C
Relative humidity 10...95 %
Mounting type Mounting rail
Weight 150 g
Max. length of the connection cables 100 m
Screw terminals yes
Pluggable connection terminals yes
Min. connection cross section 0.5 mm²
Max. connection cross section 2.5 mm²
Slot for memory card (350EPS) present yes
Connection present on PC yes
Connection to slave modules yes
Max. number of slave modules 14
Max. number of slave modules of the same type 4
Certified in accordance with EN ISO 13849-1 IEC 61508 IEC 62061 UL 508 / CSA 22.2
CE label yes
eloProg Safety Designer - Configuration software for the eloProg basic module
eloProg Safety Designer zip 232.39 MB

Software beinhaltet Benutzerhandbuch / Software includes operation manual

Certificate eloProg - TÜV Süd pdf 716.24 KB
Operating manual eloProg base module 485EPB pdf 22.57 MB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.