Skip to content
Climate neutral since 2010

Safety interlock ZM

Availabe in elostore

Safety interlock ZM

Availabe in elostore
  • 7 possible approach directions on each side of the actuator head
  • Supporting release enables the unlocking of the guard locking function in the event of a fault
  • Matching cable gland 354000 for simple installation
  • Selection of ZB actuators suitable for any application

Accessories available as an option:
Insertion funnel, bolt, screw connection and deadbolt

Actuator for safety interlocks:
ZBG5M straight without rubber bushing (R ≥ 300mm)
ZBG5G straight with rubber bushing (R ≥ 300mm)
ZBA5G angled with rubber bushing (R ≥ 300mm)
ZBG5GE straight with rubber bushing (with insertion funnel, overrun 5 mm)
ZBA5GE angled with rubber bushing (with insertion funnel, overrun 5 mm)

Hinged actuator for safety interlocks:
ZBU5M hinged actuator, approach direction top / bottom (R ≥ 200mm)
ZBL5M hinged actuator, approach direction left / right (R ≥ 100mm)
ZBU5ME hinged actuator, approach direction top / bottom (with insertion funnel, overrun 5 mm, R ≥ 200mm)
ZBL5ME hinged actuator, approach direction left / right (with insertion funnel, overrun 5 mm, R ≥ 100mm)

The small dimensions of the ZM design enable mounting even in confined installation conditions. Thanks to the simple external shape, the robust safety interlock is easy to mount.

Ce produit est également disponible dans notre elo.store.

Technical drawing

1/3
ZM-01
Full screen
1/3
2/3
ZM-02
Full screen
2/3
3/3
ZM_electrical_drawing
Full screen
3/3

Article characteristics

  • ZMA1030V
  • ZMA1120V
  • ZMR1030V
  • ZMR1120V
  • Min. switching voltage
  • Min. switching voltage
  • Min. switching current
  • Conv. thermal continuous current Ith
  • Utilization category
  • Rated insulation voltage (Ui)
  • Rated impulse withstand voltage (Uimp)
  • Magnet operating voltage +10%/-15%
  • Power consumption
  • Power-on time ED
  • Open-circuit principle
  • Closed-circuit principle
  • Switching principle
  • Short-circuit protection in accordance with IEC 60269-1 (fuse)
  • Conditional short circuit current
  • Pollution degree
  • B10d acc. to EN ISO 13849-1
  • Type acc. to EN ISO 14119
  • Mission time in years
  • Service life, mechanical (Cycles)
  • Dimensions
  • Emergency release present
  • Auxiliary unlocking device present
  • Emergency unblocking present
  • Locking force Fmax
  • Locking force FzH
  • Immersion depth
  • Overrun max.
  • Number of N.C. door position
  • Number of N.O. door position
  • Number of interlocks guard locking
  • Number of N.O. guard locking
  • Number of interlocks door position
  • Operating speed max.
  • Actuation frequency
  • Actuation force/attraction force/retention force
  • Housing material
  • Housing colour
  • Contact material
  • Protection class
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
  • Mounting type
  • Weight
  • Installation
  • Connection type
  • Min. connection cross section
  • Max. connection cross section
  • Certified in accordance with
  • CE label
AttributeZMA1030VZMA1120VZMR1030VZMR1120V
Bestellung
Bestellung
Min. switching voltage 24 V DC
Min. switching voltage 24 V AC
Min. switching current 1 A
Conv. thermal continuous current Ith 4 A
Utilization category AC-15 4A 230V / DC-13 4A 24V
Rated insulation voltage (Ui) 250 V
Rated impulse withstand voltage (Uimp) 2500 V
Magnet operating voltage +10%/-15% 24 V AC/DC
Power consumption 6 W
Power-on time ED 100 %
Open-circuit principle yes
Closed-circuit principle yes
Switching principle Slow-action switch
Short-circuit protection in accordance with IEC 60269-1 (fuse) 4 A gG
Conditional short circuit current 100 A
Pollution degree 3
B10d acc. to EN ISO 13849-1 2000000
Type acc. to EN ISO 14119 2
Mission time in years 20 a
Service life, mechanical (Cycles) 1 x 10^6
Dimensions 37,5 x 79 x 96 mm (H/B/T)
Emergency release present no
Auxiliary unlocking device present yes
Emergency unblocking present no
Locking force Fmax 2000 N
Locking force FzH 1500 N
Immersion depth 24.5 mm
Overrun max. 5 mm
Number of N.C. door position 0
Number of N.O. door position 0 1 0 1
Number of interlocks guard locking 1
Number of N.O. guard locking 0
Number of interlocks door position 2 1 2 1
Operating speed max. 20 m/min
Actuation frequency 1200 1/h
Actuation force/attraction force/retention force 35 / 30 / 20 N
Housing material Glasfaserverstaerkter Thermoplast
Housing colour Gehaeuse schwarz / Deckel gelb
Contact material Silberlegierung hauchvergoldet
Protection class IP67 DIN EN 60529
Operating temperature min. -20 °C
Max. operating temperature 50 °C
Min. storage temperature -20 °C
Max. storage temperature 50 °C
Mounting type screwed
Weight 500 g
Installation arbitrary
Connection type 3 x M20 x 1,5 Kabelverschraubung
Min. connection cross section 0.34 mm²
Max. connection cross section 1.5 mm²
Certified in accordance with EN ISO 60947-5-1 GS-ET-19 UL 508 / CSA 22.2
CE label yes
1/1
ZM_ordering_key
Full screen
1/1
Operating instructions and product information
Manual solenoid interlock ZM pdf 1.51 MB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.