Skip to content
Climate neutral since 2010

Safety sensor eloProtect E 165ESK

Availabe in elostore

Safety sensor eloProtect E 165ESK

Availabe in elostore
  • Available connection types: cable outlet, M12 pigtail
  • Contact form: OSSD
  • Optional LED display (3-colour)
  • Safety outputs: 2
  • Diagnostic output: 1
  • Safety inputs: 2
  • Protection class IP6K9K (ISO 20653)
  • Stand-Alone device (EDM input)
  • Smallest special design on market
  • Series connection with up to 30 sensors
  • Fastest response time

The RFID technology used in the eloProtectE sensors offers the user individual coding options. As a result, the tampering protection can be selected according to the application and increases the safety of the application.

The use of RFID technology simplifies the mounting conditions and offers larger offset values. These RFID switchesenable the installation of series connections with up to 30 sensors on a radial connection. Due to the high switching capacity of the safe outputs (400mA), a safety relay is not always necessary.

Ce produit est également disponible dans notre elo.store.

Technical drawing

1/3
Cat_MS_165_ESK_DRW1
Full screen
1/3
2/3
Cat_MS_165_ESK_CON
Full screen
2/3
3/3
Cat_MS_165_ESK_CD
Full screen
3/3

Article characteristics

  • 165ESK00J11
  • 165ESK00J12
  • 165ESK00J21
  • 165ESK00J22
  • 165ESK00J31
  • 165ESK00J32
  • 165ESK00K11
  • 165ESK00K12
  • 165ESK00K21
  • 165ESK00K22
  • 165ESK00K31
  • 165ESK00K32
  • Max. switching current at safety output
  • Max. switching current at control output
  • Contact form
  • Switching frequency
  • Assured switching distance (Sao)
  • Assured switch-off distance (Sar)
  • Minimum switching distance (S0 min)
  • Polarity reversal protection
  • Number of electronic safety outputs
  • Number of electronic control outputs
  • Number of safety inputs
  • EDM/start input
  • Start function
  • Utilization category
  • No-load current I0
  • Rated operating voltage (Ue)
  • Rated insulation voltage (Ui)
  • Rated impulse withstand voltage (Uimp)
  • Current consumption per input
  • Power consumption
  • LED display
  • Actuation
  • Switching principle
  • Hysteresis
  • wurde angepasst (Number)
  • Technology
  • Coding variant
  • Pollution degree
  • Rated switching distance (Sn)
  • Overvoltage category
  • Active surface (Number)
  • Turn-on delay (ton)
  • Readiness delay (tv)
  • Voltage drop (Ud)
  • Stabilised PELV/SELV power supply
  • Fuse operating voltage
  • Internal electronic fuse
  • Short-circuit detection
  • Cross-short detection
  • PL acc. to EN ISO 13849-1
  • SIL acc. to IEC 61508
  • SIL CL acc. to IEC 62061
  • PFHD according to IEC 61508
  • Category acc. to EN ISO 13849-1
  • Coding acc. to EN ISO 14119
  • Type acc. to EN ISO 14119
  • Mission time in years
  • Structure acc. to EN ISO 13849-1
  • Hardware fault tolerance (HFT) according to IEC 61508
  • Housing design
  • Dimensions
  • Free zone
  • Actuation frequency
  • Minimum installation distance (between two sensors)
  • cannot be mounted flush
  • Housing material
  • Cable material
  • Housing colour
  • Protection class, connector
  • Operating temperature min.
  • Max. operating temperature
  • Min. cable temperature range, moving
  • Max. cable temperature range, moving
  • Min. cable temperature range, fixed installation
  • Max. cable temperature range, fixed installation
  • Shock resistance (Norm)
  • Vibration resistance (Norm)
  • Protection class, housing
  • Min. storage temperature
  • Max. storage temperature
  • Continuous shock resistance (Norm)
  • Relative humidity
  • Air pressure
  • Delta tmax
  • Mounting type
  • Weight
  • Torque for fastening screws
  • Connector type
  • Cable type
  • Cable length
  • Number of strands
  • Wire cross section
  • Cable colour
  • Certified in accordance with
  • CE label
  • Possible actuators
Attribute165ESK00J11165ESK00J12165ESK00J21165ESK00J22165ESK00J31165ESK00J32165ESK00K11165ESK00K12165ESK00K21165ESK00K22165ESK00K31165ESK00K32
Bestellung
Bestellung
Max. switching current at safety output 0.4 A 0.4 A
Max. switching current at control output 0.05 A 0.05 A
Contact form OSSD OSSD
Switching frequency 3 Hz 3 Hz
Assured switching distance (Sao) 8 mm 8 mm
Assured switch-off distance (Sar) 18 mm 18 mm
Minimum switching distance (S0 min) 0.5 mm 0.5 mm
Polarity reversal protection yes yes
Number of electronic safety outputs 2 2
Number of electronic control outputs 1 1
Number of safety inputs 2 2
EDM/start input yes yes
Start function automatic monitored automatic monitored automatic monitored automatic monitored automatic monitored
Utilization category AC-12 / DC-13 AC-12 / DC-13
No-load current I0 30 mA 30 mA
Rated operating voltage (Ue) 24 V 24 V
Rated insulation voltage (Ui) 50 V 50 V
Rated impulse withstand voltage (Uimp) 1000 V 1000 V
Current consumption per input 2.75 mA 2.75 mA
Power consumption 24 W 24 W
LED display three-coloured three-coloured
Actuation arbitrary arbitrary
Switching principle electronic electronic
Hysteresis 2 mm 2 mm
wurde angepasst (Number) 30 30
Technology RFID RFID
Coding variant coded unikat individually coded coded unikat individually coded
Pollution degree 2 2
Rated switching distance (Sn) 12 mm 12 mm
Overvoltage category II II
Active surface (Number) 1 1
Turn-on delay (ton) 75 ms 75 ms
Readiness delay (tv) 1000 ms 1000 ms
Voltage drop (Ud) 0.75 V 0.75 V
Stabilised PELV/SELV power supply required required
Fuse operating voltage 1A fast 1A fast
Internal electronic fuse yes yes
Short-circuit detection yes yes
Cross-short detection yes yes
PL acc. to EN ISO 13849-1 e e
SIL acc. to IEC 61508 3 3
SIL CL acc. to IEC 62061 3 3
PFHD according to IEC 61508 2,24x10^-9 1/h 2,24x10^-9 1/h
Category acc. to EN ISO 13849-1 4 4
Coding acc. to EN ISO 14119 Low High Low High
Type acc. to EN ISO 14119 4 4
Mission time in years 20 a 20 a
Structure acc. to EN ISO 13849-1 Two-channel Two-channel
Hardware fault tolerance (HFT) according to IEC 61508 1 1
Housing design rectangular rectangular
Dimensions 25 x 88 x 13 mm 25 x 88 x 13 mm
Free zone 50 mm 50 mm
Actuation frequency 180 1/h 180 1/h
Minimum installation distance (between two sensors) 150 mm 150 mm
cannot be mounted flush yes yes
Housing material PBT, PC PBT, PC
Cable material PVC PVC
Housing colour grau, schwarz grau, schwarz
Protection class, connector IP67 / IP69K DIN EN 60529
Operating temperature min. -25 °C -25 °C
Max. operating temperature 70 °C 70 °C
Min. cable temperature range, moving -5 °C -5 °C
Max. cable temperature range, moving 80 °C 80 °C
Min. cable temperature range, fixed installation -30 °C -30 °C
Max. cable temperature range, fixed installation 80 °C 80 °C
Shock resistance (Norm) 30 g / 11 ms 30 g / 11 ms
Vibration resistance (Norm) 10 ... 55 Hz 10 ... 55 Hz
Protection class, housing IP67 DIN EN 60529 - IP6K9K ISO 20653 IP67 DIN EN 60529 - IP6K9K ISO 20653
Min. storage temperature -25 °C -25 °C
Max. storage temperature 70 °C 70 °C
Continuous shock resistance (Norm) 10 g / 16 ms 10 g / 16 ms
Relative humidity 5 - 85 % 5 - 85 %
Air pressure 860 - 1060 hPa 860 - 1060 hPa
Delta tmax 0.5 °C/min 0.5 °C/min
Mounting type screwed screwed
Weight 70 g 100 g
Torque for fastening screws 0.7 N m 0.7 N m
Connector type M12x1 - 8 polig
Cable type LiYY LiYY
Cable length 0.15 m 1 m
Number of strands 8 8
Wire cross section 0.25 mm² 0.25 mm²
Cable colour grau grau
Certified in accordance with EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.17 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.19 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.21 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.23 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.25 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.27 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.16 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.18 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.20 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.22 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.24 EN ISO 13849-1 IEC 61508 IEC 62061 EN 60947-5-3 UL 508 / CSA 22.26
CE label yes yes
Possible actuators 165EBK001 165EBK001
1/2
165ESK_switching-distance
Full screen
1/2
2/2
165ESK_ordering_key
Full screen
2/2
Operating instructions and product information
TÜV-Zertifikat eloProtect E pdf 396.87 KB
EC-Type eloProtect E pdf 313.01 KB
Flyer eloProtect E EN pdf 867.52 KB
Operating instructions eloProtect E 165ESK pdf 7.14 MB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.