  • Small standard design for installation in confined confined spaces
  • Sensors in standard or reinforced version for Switching distance to suit the application
  • Variable connection through cable outlet and M8 housing connector
  • Simple diagnosis through optional LED and control contact

Safety doors, bonnets or covers can be safely monitored with the non-contact and therefore wear-free sensors in combination with the matching elobau safety evaluation unit. The magnetic safety sensors are particularly convincing for monitoring safety doors on food processing machines due to their concealed installation behind stainless steel.

The high number of variants at elobau offers solutions for almost all applications.

Ce produit est également disponible dans notre elo.store.

Technical drawing

1/3
Safety sensor 153 - elobau
Full screen
1/3
2/3
Safety sensor 153 - elobau
Full screen
2/3
3/3
Safety sensor 153 - elobau
Full screen
3/3

Article characteristics

  • 153270
  • 153270AA
  • 153270A0E
  • 153270S
  • 153270SA0D
  • 153V62
  • 153270SA
  • 153V62A0D
  • 153V62SHD
  • 153270A0D
  • 153V62S
  • 153570AA
  • 153V62SHDPC
  • 153V62SPC
  • 153270SA0DPC
  • 153270SPC
  • Housing colour
  • Cable type
  • Cable colour
  • Detent present
  • Installation
  • Certified in accordance with
  • CE label
  • Contact form
  • Min. switching voltage
  • Max. switching voltage
  • Max. switching current
  • Max. switching current with LED
  • Max. switching power
  • Switching frequency
  • Assured switching distance (Sao)
  • Assured switch-off distance (Sar)
  • Minimum switching distance (S0 min)
  • LED display
  • Actuation
  • Switching principle
  • Series resistor
  • Technology
  • Min. switching current
  • Coding acc. to EN ISO 14119
  • B10d acc. to EN ISO 13849-1
  • Type acc. to EN ISO 14119
  • Mission time in years
  • Structure acc. to EN ISO 13849-1
  • Housing design
  • Dimensions
  • Minimum installation distance (between two sensors)
  • cannot be mounted flush
  • Housing material
  • Cable material
  • Protection class
  • Protection class, connector
  • Operating temperature min.
  • Max. operating temperature
  • Min. cable temperature range, moving
  • Max. cable temperature range, moving
  • Min. cable temperature range, fixed installation
  • Max. cable temperature range, fixed installation
  • Min. storage temperature
  • Max. storage temperature
  • Mounting type
  • Possible actuators
  • Installation opening
  • Weight
  • Connector type
  • Cable length
  • Number of strands
  • Wire cross section
Attribute153270153270AA153270A0E153270S153270SA0D153V62153270SA153V62A0D153V62SHD153270A0D153V62S153570AA153V62SHDPC153V62SPC153270SA0DPC153270SPC
Bestellung
Bestellung
Housing colour schwarz schwarz Gelb
Cable type LIYY 4 x 0,25 mm LIYY 4 x 0,25 mm LIYY 4 x 0,25 mm LIYY 4 x 0,25 mm LiYY 6x0,22 (AWG 24) LIYY 4 x 0,25 mm LIYY 4 x 0,25 mm
Cable colour schwarz
Detent present no no no
Installation arbitrary
Certified in accordance with ETL ETL CE ETL CE CE, ETL
CE label yes yes yes
Contact form NO/NC NO/NC NO/NO NO/NC NO/NO NO/NC/NO (Kontrollkontakt) NO/NO NO/NC
Min. switching voltage 0 V DC 19.2 V DC 19.2 V DC 19.2 V DC
Max. switching voltage 28.8 V DC 28.8 V DC 28.8 V DC
Max. switching current 0.1 A 0.1 A 0.1 A
Max. switching current with LED 0.01 A 0.01 A 0.01 A 0.01 A
Max. switching power 3 W
Switching frequency 5 Hz 5 Hz 5 Hz 5 Hz
Assured switching distance (Sao) 1 mm 9 mm 3 mm 9 mm 3 mm 8 mm 1 mm 8 mm 4 mm 8 mm 9 mm
Assured switch-off distance (Sar) 13 mm 21 mm 10 mm 21 mm 11 mm 17 mm 13 mm 17 mm 16 mm 17 mm 21 mm
Minimum switching distance (S0 min) 0.5 mm 0.5 mm 0.5 mm
LED display No single-coloured No single-coloured No single-coloured No single-coloured No
Actuation front front front
Switching principle magnetic magnetic magnetic
Series resistor 22 Ohm 22 Ohm 22 Ohm
Technology Reed Reed Reed
Min. switching current 0 A
Coding acc. to EN ISO 14119 Low Low Low
B10d acc. to EN ISO 13849-1 20000000 20000000 20000000
Type acc. to EN ISO 14119 4 4 4
Mission time in years 20 a 20 a 20 a
Structure acc. to EN ISO 13849-1 Two-channel Two-channel Two-channel
Housing design cuboid cuboid cuboid cuboid
Dimensions 36x26x13 36x26x13 36x26x13
Minimum installation distance (between two sensors) 50 mm
cannot be mounted flush yes yes yes
Housing material PBT PBT PBT
Cable material PVC PVC PVC PVC PVC PVC
Protection class IP67 DIN EN 60529 IP67 DIN EN 60529 IP67 DIN EN 60529
Protection class, connector IP65 DIN EN 60529
Operating temperature min. -25 °C -25 °C -25 °C -25 °C
Max. operating temperature 75 °C 75 °C 100 °C 75 °C 75 °C
Min. cable temperature range, moving -10 °C
Max. cable temperature range, moving 105 °C
Min. cable temperature range, fixed installation -30 °C
Max. cable temperature range, fixed installation 105 °C
Min. storage temperature -25 °C -25 °C -25 °C -25 °C
Max. storage temperature 75 °C 75 °C 75 °C 75 °C
Mounting type screwed from above screwed from above screwed from above
Possible actuators 30428112A , 30428102A 30428112S , 30428102S 30428112S 30428112B, 30428102B 30428102BS , 30428112BS 30428112A 30428102BS , 30428112BS 30428112A 30428112BSPC 30428112SPC
Installation opening 4.5mm 4.5mm 4.5mm
Weight 56 g 56 g
Connector type M8x1 4-polig M8x1 4-polig M8x1 4-polig M8x1 4-polig M8x1 4-polig
Cable length 1 m 1 m 1 m 1 m 1 m 1 m
Number of strands 4 4 6 4
Wire cross section 0.25 mm² 0.25 mm² 0.23 mm² 0.25 mm²
1/3
Safety sensor 153 - elobau
Full screen
1/3
2/3
Safety sensor 153 - elobau
Full screen
2/3
3/3
Safety sensor 153 - elobau
Full screen
3/3

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.