We look ahead

The Covid-19 pandemic is still affecting significant parts of our lives ...

Ultrasonic sensor 2UF Off-Highway

Ultrasonic sensor 2UF Off-Highway

  • Reliable and precise measuring
  • PA housing material
  • Operating ranges up to 1.8 m (depending on
    temperature range and use with focus tube)
  • Temperature range -40 °C…+105 °C
  • Analogue output
  • EMC resistance in accordance with DIN EN 13309,
    ISO 13766, DIN EN 1498

This special version of the ultrasonic sensor is specially suited for reliably detecting the fill level of mobile machines. The extreme temperature range as well as the high protection class are prerequisites for succeeding in these applications. Through the optional use of a focus tube, precise measurement is possible with agitated media as well as at an incline.

In addition to mobile applications, stationary applications are always possible. The fill level is output via either a voltage or current output.

Tip: More readily available with the NBR flat seal and in lengths of 400 / 600 / 800 / 1,000 mm

Technical drawing

1/6
Cat_LEV_2UF1___01_Kunststoff_mit_Rohr_DRW1
Full screen
1/6
2/6
Cat_LEV_2UF1___01_Kunststoff_mit_Rohr_CON
Full screen
2/6
3/6
Cat_LEV_2UF1___01_Kunststoff_mit_Rohr_CD
Full screen
3/6
4/6
Cat_LEV_2UF1___00_Kunststoff_ohne_Rohr_DRW1
Full screen
4/6
5/6
Cat_LEV_2UF1___01_Kunststoff_mit_Rohr_FCT
Full screen
5/6
6/6
Cat_LEV_2UF1___00_Kunststoff_ohne_Rohr_FCT
Full screen
6/6

Article characteristics

  • Attribute
  • 2UF1....10.AA00
  • 2UF1....10.AA01
  • 2UF1....70.AA00
  • 2UF1....70.AA01
  • Attribute
  • Polarity reversal protection
  • Outputs
  • Output signal min.
  • Output signal max.
  • Output signal min.
  • Output signal max.
  • Operating voltage min.
  • Operating voltage max.
  • Current consumption
  • Technology
  • Operating frequency
  • Opening angle of sound cone
  • Linearity error
  • Blind zone
  • Blind zone from sealing surface
  • Measurement accuracy
  • Repeating accuracy
  • EMC
  • Filtering time
Attribute2UF1....10.AA002UF1....10.AA012UF1....70.AA002UF1....70.AA01
Bestellung
Bestellung
Polarity reversal protection yes
Outputs 4...20mA 0,5...4,5V
Output signal min. 0.5 V DC
Output signal max. 4.5 V DC
Output signal min. 4 mA
Output signal max. 20 mA
Operating voltage min. 8 V DC
Operating voltage max. 36 V DC
Current consumption 10...35 mA
Technology Ultrasonic
Operating frequency 135 kHz
Opening angle of sound cone 12 °
Linearity error 2 %
Blind zone 56 mm
Blind zone from sealing surface 85 mm
Measurement accuracy 2 mm
Repeating accuracy 2 mm
EMC DIN EN 13309 ; DIN EN ISO 14982 ; ISO 13766
Filtering time 20 s 1 s 20 s 1 s
  • Attribute
  • 2UF1....10.AA00
  • 2UF1....10.AA01
  • 2UF1....70.AA00
  • 2UF1....70.AA01
  • Attribute
  • Housing material
  • Sealing material
  • Focus tube material
Attribute2UF1....10.AA002UF1....10.AA012UF1....70.AA002UF1....70.AA01
Bestellung
Bestellung
Housing material PA12
Sealing material NBR
Focus tube material PA6 / ohne Rohr
  • Attribute
  • 2UF1....10.AA00
  • 2UF1....10.AA01
  • 2UF1....70.AA00
  • 2UF1....70.AA01
  • Attribute
  • Protection class
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
  • Shock resistance (Norm)
  • Vibration resistance (Norm)
  • Pressure resistance
Attribute2UF1....10.AA002UF1....10.AA012UF1....70.AA002UF1....70.AA01
Bestellung
Bestellung
Protection class IP67 DIN EN 60529 / IPX9K ISO 20653
Operating temperature min. -40 °C
Max. operating temperature 105 °C
Min. storage temperature -40 °C
Max. storage temperature 105 °C
Shock resistance (Norm) DIN 68 Teil 2-27
Vibration resistance (Norm) DIN 68 Teil 2-6
Pressure resistance 1,5 bar
  • Attribute
  • 2UF1....10.AA00
  • 2UF1....10.AA01
  • 2UF1....70.AA00
  • 2UF1....70.AA01
  • Attribute
  • Mounting type
  • Installation opening
  • Torque for fastening screws
  • Diameter of focus tube
  • Bolt circle
Attribute2UF1....10.AA002UF1....10.AA012UF1....70.AA002UF1....70.AA01
Bestellung
Bestellung
Mounting type 4-hole flange
Installation opening 40 mm
Torque for fastening screws 2 N m
Diameter of focus tube 39.4 mm
Bolt circle 65 mm
  • Attribute
  • 2UF1....10.AA00
  • 2UF1....10.AA01
  • 2UF1....70.AA00
  • 2UF1....70.AA01
  • Attribute
  • Connector type
Attribute2UF1....10.AA002UF1....10.AA012UF1....70.AA002UF1....70.AA01
Bestellung
Bestellung
Connector type AMP-Superseal
1/1
2UF_ordering-key
Full screen
1/1
Manual ultrasonic sensor 2UF
Manual ultrasonic sensor 2UF pdf 2 MB
Chemical_Resistance_Titel
Chemical resistance pdf 2 MB

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.