Robust Joystick J4 Base

Robust Joystick J4 Base

  • Robust joystick for installation from above
  • Space-saving design
  • High reliability and long service life thanks to contactless Hall-effect and reed technology
  • Available with different output signals: analogue, redundant, CAN bus connection (CANopen/SAEJ1939) or with switching output
  • IP67 protection class of electronics, ideal for harsh environmental conditions
  • Deflection ±20°
  • Available with various actuation types: no-detent, detent, with friction brake or centre position interlock, any functioncan be optimally operated
  • Designed for extremely heavy loads (x-/y-axis: 2000 N, z-axis: 700 N at 190 mm lever length each)

Robust, top mounted.

The J4 robust joystick is ideal for high-stress and high-frequency use thanks to its robust design. It was designed for use in mobile machinery, such as wheel loaders for operating the bucket functions.

Technical drawing

1/3
J4_Joystick_Technik
Full screen
1/3
2/3
J4_electrical_drawing
Full screen
2/3
3/3
J4_options
Full screen
3/3

Article characteristics

  • Electrical data
  • J4A6...
  • J4C6...CANopen
  • J4C6...SAE_J1939
  • Electrical data
  • Polarity reversal protection
  • Output signal min.
  • Output signal max.
  • Output signal
  • Output signal - centre position/zero position
  • EMC immunity (Norm)
  • EMC emission (Norm)
  • Operating voltage min.
  • Operating voltage max.
  • Current consumption
  • Load resistance min.
  • Short-circuit resistance to GND
  • Short-circuit resistance to supply
  • Technology
  • Protocol
  • Transmitting cycle
  • Baud rate
  • Bus terminating resistor
AttributeJ4A6...J4C6...CANopenJ4C6...SAE_J1939
Bestellung
Polarity reversal protection yes
Output signal min. 0.5 V DC
Output signal max. 4.5 V DC
Output signal analogue
Output signal - centre position/zero position 2.5 V DC
EMC immunity (Norm) DIN EN 13309, DIN EN ISO 14982
EMC emission (Norm) DIN EN 13309, DIN EN ISO 14982
Operating voltage min. 4.5 V DC 9 V DC
Operating voltage max. 5.5 V DC 36 V DC
Current consumption max. 15 mA < 120 mA
Load resistance min. 20000 Ohm
Short-circuit resistance to GND yes
Short-circuit resistance to supply yes
Technology Hall
Protocol CANopen J1939
Transmitting cycle 100 ms
Baud rate 250 kBit/s
Bus terminating resistor no
  • Mechanical data
  • J4A6...
  • J4C6...CANopen
  • J4C6...SAE_J1939
  • Mechanical data
  • Max. lever load with specified lever length
  • Deflection
  • Service life, mechanical (Cycles)
AttributeJ4A6...J4C6...CANopenJ4C6...SAE_J1939
Bestellung
Max. lever load with specified lever length 190 mm / 2000 N
Deflection ± 20 °
Service life, mechanical (Cycles) 2000000
  • Environmental conditions
  • J4A6...
  • J4C6...CANopen
  • J4C6...SAE_J1939
  • Environmental conditions
  • Protection class, electronic
  • Operating temperature min.
  • Max. operating temperature
  • Min. storage temperature
  • Max. storage temperature
AttributeJ4A6...J4C6...CANopenJ4C6...SAE_J1939
Bestellung
Protection class, electronic IP67 DIN EN 60529
Operating temperature min. -25 °C
Max. operating temperature 85 °C
Min. storage temperature -40 °C
Max. storage temperature 85 °C
  • Installation
  • J4A6...
  • J4C6...CANopen
  • J4C6...SAE_J1939
  • Installation
  • Installation
  • Mounting type
AttributeJ4A6...J4C6...CANopenJ4C6...SAE_J1939
Bestellung
Installation from above
Mounting type screwed from above
  • Connection
  • J4A6...
  • J4C6...CANopen
  • J4C6...SAE_J1939
  • Connection
  • Connector type
  • Cable type
  • Cable length
AttributeJ4A6...J4C6...CANopenJ4C6...SAE_J1939
Bestellung
Connector type Mini-Fit Jr.
Cable type FLRY
Cable length 0.3 m

Customer reviews

We focus on public welfare economics and recycling management

Sustainability at Elobau

Product has been added to watchlist.

Data security and the limitation of data collection are very important to us. Further information on this can be found in our data privacy policy.

I agree that elobau GmbH & Co.KG and the subsidiaries group may contact me by e-mail or telephone. This can be revoked at any time by sending an e-mail message to datenschutz@elobau.de. The data provided are electronically transmitted by elobau GmbH & Co KG or to its subsidiaries, stored in the internal e-mail system and processed for offers and consultation. While the data may be stored by the provider under certain circumstances, it is handled in compliance with data protection regulations and subsequently deleted. Furthermore, the data remains with elobau group and is not disclosed to third parties, unless the inquiry is made from without the countries in which the companies are located, and disclosing the data to one of our trading partners is required in order to process the inquiry. I am aware that this may be a country outside the EU. I agree to this by the submission of this form.

The data sent will only be processed for the purpose of processing your inquiry. The data will be deleted as soon as it is no longer required for its original purpose. You can withdraw your consent at any time without providing a reason at: datenschutz@elobau.de. There are no adverse consequences. You have a right to information, deletion and restriction of the processing of your personal data.
Accept privacy policy
All entries marked with a * are mandatory.