Operating distance (Sao) from 4 to 7 mm
Switch-off distance (Sar) from 14 to 23 mm
You can find type examination certificate BVS 03 ATEX E 126 X under "Downloads". Also observe the operating instructions.
type | can be installed in zone |
671 271 I40 and 671 271 K40 |
Cat. 1G / Zone 0 (ia)* Cat. 1D / Zone 20 (ia) |
671 271 I.012 and 671 271 K.012 |
Cat. 1/2 G / partition wall zone 0/1 (ia) Cat. 2G / Zone 1 (ia) Cat. 1D / Zone 20 (ia) Cat. 2D / Zone 21 (ib) |
671 271 M.0 and 671 271 N.0 |
Cat. 2G / Zone 1 (mb) Cat. 2D / Zone 21 (mb) |
* ony with shielded cable
671271..0 | Product inquiry |
certificate no. | BVS 03 ATEX E 126 X |
resistance | DCA 1206/22 Ω/0,25 W |
protection class | IP 68 10 bar |
contact form | N.O./N.C. |
switching voltage | 24 V AC/DC |
switching current I1, I2 | 0,5 A |
switching power | 5 W/VA |
nominal current I1+I2 | max. 60 mA |
temperature range T5/2D | -25…+85°C |
T6 | -25…+70°C |
nominal voltage | Ui = 24 V AC/DC |
power | Pi = 0,5 W |