Sensor with approval RL 94/9 (ATEX)
Before installing this sensor, please read the instruction „machine safety switch sensors series 671“ and the operation manual.
Please use the button "productfinder" for defining one of these products.
|
 |
| Article
No. |
material |
can be installed in zone |
explosion protection types |
certificate no. |
| 671262..0 |
VA/Ms vernickelt - stainless steel/brass - acier inox. / laiton |
Cat. 1 G / Zone 0 (ia)*
Cat. 1/2 G / Trennwand / partition wall zone / mur de separation Zone 0/1 (ia) Cat. 2 G / Zone 1 (ia)
Cat. 2 G / Zone 1 (m)
Cat. 2 D / Zone 21 (m) |
Ex II 1 G EEx ia IIB T6/T5 Ex II 1/2 G EEx ia IIC T6/T5
Ex II 2 G EEx ia IIC T6/T5 Ex II 2 G EEx m II T5/T6 Ex II 2 D IP68 10 bar T 105°C |
BVS 03 ATEX E 126 X CE 0123 |
|
 |
| Article
No. |
magnet system |
air gaps for reliable switching function |
resistance |
protection class |
| 671262..0 |
304 200 00 V.. / 304 200 00 VS/SH |
a = > 0,5 ≤ 4mm, b = min. 14mm / a = > 3 ≤ 7mm, b = min. 20mm |
DCA 1206/22 Ω/0,25 W |
IP 68 10 bar |
|
 |
| Article
No. |
contact form |
switchting voltage |
switching current I1, I2 |
switching power |
| 671262..0 |
3xSchliesser / 3xN/O / 3xcontacteur |
24 V AC/DC |
0,5 A |
5 W/VA |
|
 |
| Article
No. |
nominal current I1+I2 |
temperature range T5/2D |
T6 |
nominal voltage |
| 671262..0 |
max. 60 mA / max. 150 mA |
-25…+85°C / -25…+70°C |
-25…+70°C / -25…+50°C |
Ui = 24 V AC/DC |
|
 |
| Article
No. |
power |
Downloads |
Product
inquiry |
Productfinder |
| 671262..0 |
Pi = 0,5 W |
 |
 |
|
|