Before installing this sensor, please read the instruction „machine safety switch sensors series 671“ and the operation manual.
air gaps for reliable switching function:
magnet system 30420000V..: a = > 0,5 ≤ 4 mm, b = min. 11 mm, c = min.16 mm
magnet system 30420000V..: a = > 3 ≤ 7 mm, b = min. 17 mm, c = min. 23 mm
Please use the button "productfinder" for defining one of these products.
|
 |
| Article
No. |
material |
can be installed in zone |
explosion protection types |
certificate no. |
| 671271..0 |
VA/stainless steel/acier inoxydable / Ms vernickelt/brass/laiton |
Cat. 1 G / Zone 0 (ia)*
Cat. 1/2 G / Trennwand / partition wall zone / mur de separation Zone 0/1 (ia) Cat. 2 G / Zone 1 (ia)
Cat. 2 G / Zone 1 (m)
Cat. 2 D / Zone 21 (m) |
Ex II 1 G EEx ia IIB T6/T5 Ex II 1/2 G EEx ia IIC T6/T5
Ex II 2 G EEx ia IIC T6/T5 Ex II 2 G EEx m II T5/T6 Ex II 2 D IP68 10 bar T 105°C |
BVS 03 ATEX E 126 X CE 0123 |
|
 |
| Article
No. |
resistance |
protection class |
contact form |
switchting voltage |
| 671271..0 |
DCA 1206/22 Ω/0,25 W |
IP 68 10 bar |
Schliesser/Öffner / N/O/N/C / contacteur/rupteur |
24 V AC/DC |
|
 |
| Article
No. |
switching current I1, I2 |
switching power |
nominal current I1+I2 |
temperature range T5/2D |
| 671271..0 |
0,5 A |
5 W/VA |
max. 60 mA max. 150 mA |
-25…+85°C -25...+70°C |
|
 |
| Article
No. |
T6 |
nominal voltage |
power |
Downloads |
| 671271..0 |
-25…+70°C -25...+50°C |
Ui = 24 V AC/DC |
Pi = 0,5 W |
 |
|
 |
| Article
No. |
Product
inquiry |
Productfinder |
|
|
| 671271..0 |
 |
|
|
|
|