approved to RL 94/9 (ATEX)
Before installing this sensor, please read the instruction „proximity switch series 6“ and the operation manual.
Please use the button "productfinder" for defining one of these products.
|
 |
| Article
No. |
material |
can be installed in zone |
explosion protection types |
certificate no. |
| 650310..0 |
VA |
Cat. 1 G / Zone 0 (ia)*
Cat. 1/2 G / Trennwand / partition wall zone / mur de separation Zone 0/1 (ia) Cat. 2 G / Zone 1 (ia)
Cat. 2 G / Zone 1 (m)
Cat. 2 D / Zone 21 (m) |
Ex II 1 G EEx ia IIB T6/T5 Ex II 1/2 G EEx ia IIC T6/T5
Ex II 2 G EEx ia IIC T6/T5 Ex II 2 G EEx m II T6/T5 Ex II 2 D IP67 T 105°C |
BVS 03 ATEX E 126 X CE 0123 |
| 650330..0 |
VA |
Cat. 1 G / Zone 0 (ia)*
Cat. 1/2 G / Trennwand / partition wall zone / mur de separation Zone 0/1 (ia) Cat. 2 G / Zone 1 (ia)
Cat. 2 G / Zone 1 (m)
Cat. 2 D / Zone 21 (m) |
Ex II 1 G EEx ia IIB T6/T5 Ex II 1/2 G EEx ia IIC T6/T5
Ex II 2 G EEx ia IIC T6/T5 Ex II 2 G EEx m II T6/T5 Ex II 2 D IP67 T 105°C |
BVS 03 ATEX E 126 X CE 0123 |
|
 |
| Article
No. |
DC |
AC |
protection class 529 |
temperature range T5/2D |
| 650310..0 |
250/3/100 V/A/W |
250/3/100 V/A/VA |
IP 67 |
-25…+85°C |
| 650330..0 |
230/1/60 V/A/W |
230/1/60 V/A/VA |
IP 67 |
-25…+85°C |
|
 |
| Article
No. |
temperature range T6 |
contact form |
nominal voltage |
nominal current |
| 650310..0 |
-25…+70°C |
Schließer, N/O, contacteur |
Ui = 60 V UC |
li = 3 A |
| 650330..0 |
-25…+70°C |
Wechsler, C/O, inverseur |
Ui = 60 V UC |
li = 1 A |
|
 |
| Article
No. |
power |
Downloads |
Product
inquiry |
Productfinder |
| 650310..0 |
Pi = 500 mW |
 |
 |
|
| 650330..0 |
Pi = 500 mW |
 |
 |
|
|