elobau

Intelligent interface 363.97


  • Interface for input expansion
  • Can be used up to PL "d" (category 3) in accordance with EN ISO 13849-1 or SIL2 in accordance with IEC 61508
  • 4 safe inputs with 2 N.O. contacts each
  • 1 safety output
  • 4 control outputs 363V97, 1 control output 363G97
  • For use with the following safety control units: 46311.B., 47011.B., 471EFR
363V97 Product inquiry
operating voltage 24 V DC 10%
current consumption 50 mA
control outputs 4
switching voltage 24 V DC 10% (safety output an control outputs)
switching current safety output max. 20 mA
switching current control outputs each channel max. 200 mA
safety characteristics SIL CL: 2 / PL: d / cat.: 3
PFHD 1,05e-8
material of housing PA
temperature range 0C...+55C
elobau worldwide
Download catalogue Machine Safety