363V97 | Product inquiry |
operating voltage | 24 V DC ±10% |
current consumption | 50 mA |
control outputs | 4 |
switching voltage | 24 V DC ±10% (safety output an control outputs) |
switching current safety output | max. 20 mA |
switching current control outputs | each channel max. 200 mA |
safety characteristics | SIL CL: 2 / PL: d / cat.: 3 |
PFHD | 1,05e-8 |
material of housing | PA |
temperature range | 0°C...+55°C |
new article | |
operating voltage | |
current consumption | |
control outputs | |
switching voltage | |
switching current safety output | |
switching current control outputs | |
safety characteristics | |
PFHD | |
material of housing | |
temperature range |
It is possible to connect up to 4 sensors. If less than 4 sensors are connected, unused terminals should be shorted out.