This analogue float level sensor is available with a pipe length of up to 2000 mm. The fluid level sensor is also available with a 360° rotatable head which offers additional flexibility for mounting.
The float level sensor is optionally available with LCD display or remote control for simple programming.
The float level sensor can be used for monitoring tanks in fire-fighting vehicles or for level measurement in generators and construction plant.
2..2... rotatable head |
Product inquiry |
Mounting thread | G 1,5“ or G 2“ |
Material Riser | V4A (-20°…+70°C) |
Material thread and float | PVC (-10°…+65°C) | PP (-20°…+70°C) | PA12 (-20°…+70°C) | V4A (-20°…+70°C) |
max. pipe length | 1.500 mm | 2.000 mm |
Mounting variants | Hanging or standing at incline of up to 30 |
resolution | 10 or 20 mm spacing |
operating voltage | 9-32/36 V |
output signal | 1 V...5 V, 0 V...5 V, (0 V...10 V), 0,5 V...4,5 V, 4 mA...20 mA, 0 mA...20 mA |
Display | optional |
temperature measurement | optional |
Remote control | optional |
connection | varios connector or cable glands |
protection class | up to IP69K |
2..3.. non-rotatable head |
|
Mounting thread | G 1,5“ | G 2“ | 1,5“ NPT | 2“ NPT |
Material Riser | PVC (-10°…+65°C) | PP (-20°…+70°C) | PVDF (-20°…+70°C) | V4A (-20°…+70°C) |
Material thread and float | PVC | PP | PVDF | V4A |
max. pipe length | 800 mm | 2.000 mm |
Mounting variants | Hanging or standing at incline of up to 30 |
resolution | 10 or 20 mm spacing |
operating voltage | 9-32/36 V |
output signal | 1 V…5 V, 0 V…5 V, (0 V…10 V), 0,5 V…4,5 V, 4 mA…20 mA, 0 mA…20 mA |
Display | optional |
temperature measurement | optional |
Remote control | optional |
connection | varios connector or cable glands |
protection class | up to IP69K |