The angle sensor 424A… is used for measuring angles in the range between 30° and 120°. The 424A… is based on the contactless Hall measurement principle, which is extremely reliable and ensures a long service life.
The angle sensor is typically used for the position detection of levers and flaps in agricultural and construction machinery.
424A..A.... | Product finder |
operating voltage | |
output signal | |
current consumption | |
resolution | 0,1° |
load resistance | |
centre position | |
reverse connection protected | yes |
delay time of output signal | approx. 3 ms |
temperature range | -40°C...+85°C |
protection class | IP 67 |
424A.0A.... | Product finder |
operating voltage | 10-30 V DC |
output signal | 1-5 V |
current consumption | 12 V -> 18 mA |
resolution | 0,1° |
load resistance | > 20 kΩ |
centre position | 3 V |
reverse connection protected | yes |
delay time of output signal | approx. 3 ms |
temperature range | -40…+85°C |
protection class | IP 67 |
424A.1A.... | Product finder |
operating voltage | 10-30 V DC |
output signal | 4-20 mA |
current consumption | 12 V -> 18 mA |
resolution | 0,1° |
load resistance | * |
centre position | 12 mA |
reverse connection protected | yes |
delay time of output signal | approx. 3 ms |
temperature range | -40…+85°C |
protection class | IP 67 |
424A.2A.... | Product finder |
operating voltage | 8,5 V DC |
output signal | 4-20 mA |
current consumption | 8,5 V -> 35 mA |
resolution | 0,1° |
load resistance | 200 Ω -> GND |
centre position | 12 mA |
reverse connection protected | yes |
delay time of output signal | approx. 3 ms |
temperature range | -40…+85°C |
protection class | IP 67 |
424A.6A.... | Product finder |
operating voltage | 4,5-5,5 V DC |
output signal | 0,5-4,5 V ratiom. |
current consumption | 5 V -> 8 mA |
resolution | 0,1° |
load resistance | > 20 kΩ |
centre position | typ. 2,5 V |
reverse connection protected | no |
delay time of output signal | approx. 3 ms |
temperature range | -40…+85°C |
protection class | IP 67 |
424A.7A.... | Product finder |
operating voltage | 10-30 V DC |
output signal | 0,5-4,5 V |
current consumption | 12 V -> 10 mA |
resolution | 0,1° |
load resistance | > 20 k |
centre position | typ. 2,5 V |
reverse connection protected | yes |
delay time of output signal | approx. 3 ms |
temperature range | -40…+85°C |
protection class | IP 67 |